Please give us your feedback after the live
Fill the survey →
12:30
|
Introduction
|
12:35
|
Panel discussion
|
12:55 |
What about sirolimus eluting coronary stents?
Presentation
|
13:00
|
Panel discussion
|
13:15 |
Panel discussion
|
13:30 |
Panel discussion
|
13:45 |
Takes home messages
|
Bijan B. Good job
Igor K. Great cases, excellent operators, great guidance and explanation
chisari A. Thanks for sharing the cases.
I have the following comments regarding the first case:
1) in my mind it make non sense when u performed the first knuckle wire. Vessel course was clear in that part and you just create a big hematoma making more complex the rest of the procedure. Moreover make antegrade knuckle with such big bend is a little bit risky in terms of collaterals perforation.
2) Performing standard R-Cart with 3.5 balloon in such diseased vessel without IVUS evaluation is not so safe in terms of vessel perforation.
My best