It looks like you're using an obsolete version of internet explorer. Internet explorer is no longer supported by Microsoft since the end of 2015. We invite you to use a newer browser such as Firefox, Google Chrome or Microsoft Edge.
Carotid TAVR in a patient with pure aortic regurgitation and previous surgery for aortic dissection
Become an Incathlab member and receive full access to its content!
You must be an Incathlab member to access videos without any restrictions. Register for free in one minute and access all services provided by Incathlab.You will also be able to log into Incathlab from your Facebook or twitter account by clicking on login on the top-right corner of Incathlab website.
Previous surgery : Aortic dissection in 2005 (supra coronary replacement with a tube of 30mm)
NYHA III Dyspnea with 3 episodes of acute pulmonary oedema
TTE: LEF 60%, severe AI with cusp prolaps, LV dilatation and secondary MI grade II and TI grade II
Left heart cath: Normal
EuroSCORE I 20,6%; II 6,19%, high risk surgery
Heart TEAM: off- label TAVR followed by Mitraclip in a second step if needed
Description of procedure
Main arterial acces: Left commun carotid (the only non dissected artery)
Pigtail from the right arterial artery
Aortic surface 3,4cm² and perimeter 6,7cm
Corevalve Pro 26mm with deployement on rapid pacing and TEE guidance
Strategy & approach
Discussion in Heart Team and patient jugged at high risk for redo surgery. Endovascular treatment of aortic insufficiency
Devices used
Corevalve Pro 26mm
Medical therapy
Not applied in this case
Operators:
Surgeons: Dr Fabre, Dr Hysi
Cardiologist: Dr Pécheux, Dr Hannebicque
Anesthesiologist: Dr Rebet
Bibliography
Roy DA, Schaefer U, Guetta V, Hildick-Smith D, Möllmann H, Dumonteil N, et al. Transcatheter aortic valve implantation for pure severe native aortic valve regurgitation. J Am Coll Cardiol 2013;61:1577–84.
Abdelaziz HK, Wiper A, More RS, Bittar MN, Roberts DH. Successful Transcatheter Aortic Valve Replacement Using Balloon-Expandable Valve for Pure Native Aortic Valve Regurgitation in the Presence of Ascending Aortic Dissection. J Invasive Cardiol 2018;30:E62–E63.
Caporali E, Pedrazzini G, Demertzis S, Ferrari E. Transcatheter aortic valve implantation for recurrent Valsalva sinus re-dissection and severe aortic regurgitation shortly after surgery for type-A aortic dissection. Interact Cardiovasc Thorac Surg 2017;25:839–41.
Maureira P, Liu Y, Stafford N, Fiore A, Angioi M. Transcatheter aortic valve implantation via right carotid artery route for severe aortic regurgitation management in a patient with chronic operated type A aortic dissection. Heart Surg Forum 2014;17:E242–244.
Bruschi G, Colombo P, Nava S, Musca F, Merlanti B, Belli O, et al. Evolut R Implantation to Treat Severe Pure Aortic Regurgitation in a Patient With Mitral Bioprosthesis. Ann Thorac Surg 2016;102:e521–e524.
Shooting date : 2019-02-04 Last update : 2020-03-04
Pecheux M. Fois result