×
It looks like you're using an obsolete version of internet explorer. Internet explorer is no longer supported by Microsoft since the end of 2015. We invite you to use a newer browser such as Firefox, Google Chrome or Microsoft Edge.
My Player placeholder

Become an Incathlab member and receive full access to its content!

You must be an Incathlab member to access videos without any restrictions. Register for free in one minute and access all services provided by Incathlab.You will also be able to log into Incathlab from your Facebook or twitter account by clicking on login on the top-right corner of Incathlab website.

Registration Login


Worldwide schedules comment Share
59073 views

Educational objectives

Discuss the indication of contact force monitoring on RF ablation procedures.
Understand the role of lesion visualization software on mapping and ablation procedures.
Learn about the most recent clinical results using contact force catheters and 3D mapping system in the treatment of AF and VT.

 

Chairman

Prof. Karl-Heinz Kuck, Asklepios St.Georg, Hamburg, Germany

 

Program and Speakers

Lecture 1: In vivo comparison of Contact Force guided left atrial mapping and ablation with non Contact Force guided mapping and ablation.

Dr. Roland Tilz, MD, Asklepios St.Georg, Hamburg, Germany

 

Lecture 2: Contact Force guided ablation and inter lesion distance.

Dr. Amir Jadidi, MD, Herzzentrum, Bad Krozingen, Germany


Lecture 3: Contact Force on Mapping and Ablation of Ventricular Arrhythmias.

Prof. Paolo Della Bella, San Raffaele, Milano, Italy

 

Question and Answers /  Chat

 

 

This webinar is an educational event supported by Biosense Webster Europe, a division of Johnson & Johnson Medical NV/SA, and is intended for Healthcare Professionals in Europe Middle East Africa.

IMPORTANT NOTICE

While every effort is made to see that no inaccurate or misleading data, opinions, or statements appear in this webinar, they wish to make it clear that material contained in the webinar represents independent evaluations and opinions of the authors and contributors. As a consequence, Biosense Webster Inc. organization accept no responsibility for the consequences of any such inaccurate or misleading data or statements. Neither do they endorse the content, the value of contact force used or the use of any drug or device in a way that lies outside its current licensed application in any territory. This presentation may include demonstration of the use of surgical devices; it is not intended to be used as a surgical training guide. Other surgeons may employ different techniques. The steps demonstrated may not be the complete steps of the procedure. Individual surgeon preference and experience as well as patient needs may dictate variation in procedure steps. Before using any medical device, including those demonstrated or referenced in this presentation, review all relevant package inserts, with particular attention to the indications, contraindications, warnings and precautions, and steps for use of the device.

All content of this presentation is owned by their authors and is protected by worldwide copyright laws. No modification or further reproduction of the content is permitted. The content may otherwise not be copied or used in any way.

© Johnson & Johnson Medical NV/SA 2013

7009-2013 11EMEAEXT

Shooting date : 2013-12-11
Last update : 2021-06-08
Scroll Up